Skip to main content

Table 4 Observed vs. expected metrics for feasibility of newborn screening

From: Feasibility of clinical newborn metabolic screening in a high-volume maternity center in Nepal

Metrics for feasibility

Expected outcome

Observed outcome

Sample collection competency

100%

99.9%

Sample collection within 24–48 h

100%

96.4%

Time to delivery to KTM intermediate lab (mean ± SD)

24 h

36 ± 24 h

Time to arrival at Bangalore lab (mean ± SD)

2 days

4.75 ± 1 days

Time to result communication to Provider after arrival in Bangalore Lab (Mean ± SD)

72 h

24 ± 8 h

Time to communication of result to family by healthcare provider (mean ± SD)

48 h

30 ± 18 h

Time between birth and result communication to family (Mean ± SD)

14 days

9.5 ± 2 days

Number of families contacted with results

100%

100%

Number of reports requiring confirmation/Intervention

 < 3%

1.6%